ACS Appl Nano Mater ; 7(6): 5956-5966, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38544505

RESUMO

Constant exposure to blue light emanating from screens, lamps, digital devices, or other artificial sources at night can suppress melatonin secretion, potentially compromising both sleep quality and overall health. Daytime exposure to elevated levels of blue light can also lead to permanent damage to the eyes. Here, we have developed blue light protective plasmonic contact lenses (PCLs) to mitigate blue light exposure. Crafted from poly(hydroxyethyl methacrylate) (pHEMA) and infused with silver nanoparticles, these contact lenses serve as a protective barrier to filter blue light. Leveraging the plasmonic properties of silver nanoparticles, the lenses effectively filtered out the undesirable blue light (400-510 nm), demonstrating substantial protection (22-71%) while maintaining high transparency (80-96%) for the desirable light (511-780 nm). The maximum protection level reaches a peak of 79% at 455 nm, aligned with the emission peak for the blue light sourced from LEDs in consumer displays. The presence of silver nanoparticles was found to have an insignificant impact on the water content of the developed contact lenses. The lenses maintained high water retention levels within the range of 50-70 wt %, comparable to commercial contact lenses. The optical performance of the developed lenses remains unaffected in both artificial tears and contact lens storage solution over a month with no detected leakage of the nanoparticles. Additionally, the MTT assay confirmed that the lenses were biocompatible and noncytotoxic, maintaining cell viability at over 85% after 24 h of incubation. These lenses could be a potential solution to protect against the most intense wavelengths emitted by consumer displays and offer a remedy to counteract the deleterious effects of prolonged blue light exposure.

2.
Light Sci Appl ; 12(1): 271, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37957141

RESUMO

Smart contact lenses have recently gained traction due to their functionalization as noninvasive diagnostic and therapeutic wearables that can address several ocular diseases. Herein, multifunctional contact lenses exhibiting UV-transition and temperature-responsive capabilities were developed utilizing chromogenic materials that were integrated simultaneously into poly(2-hydroxyethyl methacrylate) (pHEMA) contact lenses. The functionalities of the contact lenses were optically evaluated in both their activated and non-activated states. Transition contact lenses offered excellent UV and blue light blocking capabilities (~45%) at their inactive states. When activated via UV exposure, the transparent lenses darkened instantaneously and absorbed portions of the visible light spectrum. The absorption intensity and transient discoloration of the transition lenses relied primarily on the utilized photochromic material. Likewise, the temperature-responsive contact lenses exhibited distinct colorimetric variations in response to temperature changes within the physiological range (33-38 °C). The maximum sensitivity of the thermochromic lens was 8% transmitted light per Celsius degree shift. Physiochemical and morphological analysis indicated the adequacy of the contact lenses. Hence, the multifunctional contact lenses can be deployed as smart wearables to manage ophthalmic deficiencies that are deterred by UV radiations and variations in ocular surface temperature.

3.
Front Bioeng Biotechnol ; 11: 1105377, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37304146

RESUMO

Decellularized corneas offer a promising and sustainable source of replacement grafts, mimicking native tissue and reducing the risk of immune rejection post-transplantation. Despite great success in achieving acellular scaffolds, little consensus exists regarding the quality of the decellularized extracellular matrix. Metrics used to evaluate extracellular matrix performance are study-specific, subjective, and semi-quantitative. Thus, this work focused on developing a computational method to examine the effectiveness of corneal decellularization. We combined conventional semi-quantitative histological assessments and automated scaffold evaluations based on textual image analyses to assess decellularization efficiency. Our study highlights that it is possible to develop contemporary machine learning (ML) models based on random forests and support vector machine algorithms, which can identify regions of interest in acellularized corneal stromal tissue with relatively high accuracy. These results provide a platform for developing machine learning biosensing systems for evaluating subtle morphological changes in decellularized scaffolds, which are crucial for assessing their functionality.

4.
ACS Biomater Sci Eng ; 9(7): 4381-4391, 2023 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-37364228

RESUMO

3D printing of multimaterial objects is an emerging field with promising applications. The layer-by-layer material addition technique used in 3D printing enables incorporation of distinct functionalized materials into the specialized devices. However, very few studies have been performed on the usage of multimaterial 3D printing for printable photonic and wearable devices. Here, we employ vat photopolymerization-based 3D printing to produce multimaterial contact lenses, offering enhanced multiband optical filtration, which can be valuable for tackling ocular conditions such as color blindness. A combination of hydroxyethyl methacrylate (HEMA) and polyethylene glycol diacrylate (PEGDA) was used as the base hydrogel for 3D printing. Atto565 and Atto488 dyes were added to the hydrogel for wavelength filtering, each dye suitable for a different type of color blindness. Multimaterial disks and contact lenses, with separate sections containing distinct dyes, were 3D-printed, and their optical properties were studied. The characteristics of multimaterial printing were analyzed, focusing on the formation of a uniform multimaterial interface. In addition, a novel technique was developed for printing multiple dyed materials in complex lateral geometrical patterns, by employing suitable variations in CAD models and the UV curing time. It was observed that the multimaterial printing process does not negatively affect the optical properties of the contact lenses. The printed multimaterial contact lenses offered a combined multi-band color blindness correction due to the two dyes used. The resulting optical spectrum was a close match to the commercially available color blindness correction glasses.


Assuntos
Lentes de Contato , Impressão Tridimensional , Hidrogéis/química , Software , Teste de Materiais
5.
Front Bioeng Biotechnol ; 11: 1133122, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37180037

RESUMO

Introduction: Corneal disease is a leading cause of blindness globally that stems from various etiologies. High-throughput platforms that can generate substantial quantities of corneal grafts will be invaluable in addressing the existing global demand for keratoplasty. Slaughterhouses generate substantial quantities of underutilized biological waste that can be repurposed to reduce current environmentally unfriendly practices. Such efforts to support sustainability can simultaneously drive the development of bioartificial keratoprostheses. Methods: Scores of discarded eyes from the prominent Arabian sheep breeds in our surrounding region of the United Arab Emirates (UAE) were repurposed to generate native and acellular corneal keratoprostheses. Acellular corneal scaffolds were created using a whole-eye immersion/agitation-based decellularization technique with a widely available, eco-friendly, and inexpensive 4% zwitterionic biosurfactant solution (Ecover, Malle, Belgium). Conventional approaches like DNA quantification, ECM fibril organization, scaffold dimensions, ocular transparency and transmittance, surface tension measurements, and Fourier-transform infrared (FTIR) spectroscopy were used to examine corneal scaffold composition. Results: Using this high-throughput system, we effectively removed over 95% of the native DNA from native corneas while retaining the innate microarchitecture that supported substantial light transmission (over 70%) after reversing opacity, a well-established hallmark of decellularization and long-term native corneal storage, with glycerol. FTIR data revealed the absence of spectral peaks in the frequency range 2849 cm-1 to 3075 cm-1, indicating the effective removal of the residual biosurfactant post-decellularization. Surface tension studies confirmed the FTIR data by capturing the surfactant's progressive and effectual removal through tension measurements ranging from approximately 35 mN/m for the 4% decellularizing agent to 70 mN/m for elutes highlighting the effective removal of the detergent. Discussion: To our knowledge, this is the first dataset to be generated outlining a platform that can produce dozens of ovine acellular corneal scaffolds that effectively preserve ocular transparency, transmittance, and ECM components using an eco-friendly surfactant. Analogously, decellularization technologies can support corneal regeneration with attributes comparable to native xenografts. Thus, this study presents a simplified, inexpensive, and scalable high-throughput corneal xenograft platform to support tissue engineering, regenerative medicine, and circular economic sustainability.

6.
Nanomaterials (Basel) ; 12(9)2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35564192

RESUMO

Surface functionalization of metallic nanoparticles (NPs) with external groups can be engineered to fabricate sensors that are responsive to various stimuli like temperature, pH, and numerous ions. Herein, we report the synthesis of gold nanoparticles (GNPs) functionalized with 3-mercaptopropionic acid (GNPs-MPA) and the doping of these nanoparticles into hydrogel materials using the breathing-in/breathing-out (BI-BO) method. MPA has a carboxyl group that becomes protonated and, thus, ionized at a pH below its pKa (4.32); hence, the GNPs-MPA solutions and gels were mostly pH-responsive in the range of 3-5. Optical properties were assessed through ultraviolet-visible (UV-Vis) spectroscopy, namely: transmission and absorption, and the parameters used to quantify the pH changes were the full width at half maximum (FWHM) and position of surface plasmon resonance (SPR). The solutions and gels gradually changed their colors from red to indigo with pH decrementation from 5 to 3, respectively. Furthermore, the solutions' and doped gels' highest FWHM sensitivities towards pH variations were 20 nm and 55 nm, respectively, while the SPR's position sensitivities were 18 nm and 10 nm, respectively. Also, transmission and scanning electron microscopy showed synchronized dispersion and aggregation of NPs with pH change in both solution and gel forms. The gel exhibited excellent repeatability and reversibility properties, and its response time was instantaneous, which makes its deployment as a colorimetric pH-triggered sensor practical. To the best of our knowledge, this is the first study that has incorporated GNPs into hydrogels utilizing the BI-BO method and demonstrated the pH-dependent optical and colorimetric properties of the developed nanocomposites.

7.
ACS Biomater Sci Eng ; 8(5): 2111-2120, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35468279

RESUMO

Integration of nanomaterials into hydrogels has emerged as a prominent research tool utilized in applications such as sensing, cancer therapy, and bone tissue engineering. Wearable contact lenses functionalized with nanoparticles have been exploited in therapeutics and targeted therapy. Here, we report the fabrication of gold and silver nanocomposite commercial contact lenses using a breathing-in/breathing-out (BI-BO) method, whereby a hydrated contact lens is shrunk in an aprotic solvent and then allowed to swell in an aqueous solution containing nanoparticles. The morphology and optical properties of the gold and silver nanoparticles were characterized through transmission electron microscopy and ultraviolet-visible spectroscopy. The transmission spectra of nanocomposite contact lenses indicated that the nanoparticles' loading amount within the lens depended primarily on the number of BI-BO cycles. Nanocomposites were stable for a minimum period of 1 month, and no nanoparticle leaching was observed. Wettability and water content analysis of the nanocomposites revealed that the contact lenses retained their intrinsic material properties after the fabrication process. The dispersion of the nanoparticles within the contact lens media was determined through scanning electron microscopy imaging. The nanocomposite lenses can be deployed in color filtering and antibacterial applications. In fact, the silver nanocomposite contact lens showed blue-light blocking capabilities by filtering a harmful high-energy blue-light range (400-450 nm) while transmitting the visible light beyond 470 nm, which facilitates enhanced night vision and color distinction. The ease of fabricating these nanocomposite contact lenses via the BI-BO method could enable the incorporation of nanoparticles with diverse morphologies into contact lenses for various biomedical applications.


Assuntos
Lentes de Contato , Nanopartículas Metálicas , Nanocompostos , Ouro , Hidrogéis/química , Prata
8.
Front Med (Lausanne) ; 9: 858784, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35445050

RESUMO

Diabetes mellitus is a chronic disease requiring a careful management to prevent its collateral complications, such as cardiovascular and Alzheimer's diseases, retinopathy, nephropathy, foot and hearing impairment, and neuropathy. Self-monitoring of blood glucose at point-of-care settings is an established practice for diabetic patients. However, current technologies for glucose monitoring are invasive, costly, and only provide single snapshots for a widely varying parameter. On the other hand, tears are a source of physiological information that mirror the health state of an individual by expressing different concentrations of metabolites, enzymes, vitamins, salts, and proteins. Therefore, the eyes may be exploited as a sensing site with substantial diagnostic potential. Contact lens sensors represent a viable route for targeting minimally-invasive monitoring of disease onset and progression. Particularly, glucose concentration in tears may be used as a surrogate to estimate blood glucose levels. Extensive research efforts recently have been devoted to develop smart contact lenses for continual glucose detection. The latest advances in the field are reviewed herein. Sensing technologies are described, compared, and the associated challenges are critically discussed.

9.
Small ; 17(51): e2102876, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34605152

RESUMO

Commercial implantable continuous glucose monitoring devices are invasive and discomfort. Here, a minimally-invasive glucose detection system is developed to provide quantitative glucose measurements continually based on bifocal contact lenses. A glucose-sensitive phenylboronic acid derivative is immobilized in a hydrogel matrix and the surface of the hydrogel is imprinted with a Fresnel lens. The glucose-responsive hydrogel is attached to a commercial soft contact lens to be transformed into a bifocal contact lens. The contact lens showed bifocal lengths; far-field focal length originated from the contact lens' curvature, and near-field focal length resulting from the Fresnel lens. When tear glucose increased, the refractive index and groove depth of the Fresnel lens changed, shifting the near-field focal length and the light focusing efficiency. The recorded optical signals are detected at an identical distance far from the contact lens change. The bifocal contact lens allowed for detecting the tear glucose concentration within the physiological range of healthy individuals and diabetics (0.0-3.3 mm). The contact lens rapidly responded to glucose concentration changes and reached 90% of equilibrium within 40 min. The bifocal contact lens is a wearable diagnostic platform for continual biomarker detection at point-of-care settings.


Assuntos
Lentes de Contato Hidrofílicas , Dispositivos Eletrônicos Vestíveis , Glicemia , Automonitorização da Glicemia , Glucose , Humanos , Smartphone , Acuidade Visual
10.
ACS Nano ; 15(2): 2340-2349, 2021 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-33523623

RESUMO

Direct texturing of nanostructures on consumable substrates and products is a challenge because of incompatible ingredients and materials' properties. Here, we developed a direct laser-based method to print nanostructured holograms on dried films of consumable corn syrup solutions. A holographic laser (λ = 1050 nm) interference system was used to construct the nanostructures of the holograms on food for rainbow effects. The relationship between wavelength and periodicity contributed to the changing diffraction angle through the change of the refractive index (1.642). Increasing the sugar concentration (25-175 mg) in the syrup increased the diffraction efficiency of these holograms. The added amount of sugar in the composition increased the refractive index (7%) and decreased the light absorption (12.9%), which influenced the change of diffraction angle by 4.4°. The surface holograms displayed wideband visual diffraction of light extending from violet to red wavelengths. These holograms on edible materials can be imprinted onto commercial food products for adding aesthetic value and controlling perception.

11.
ACS Nano ; 15(3): 4870-4880, 2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33570901

RESUMO

Color vision deficiency (CVD) is an ocular congenital disorder that affects 8% of males and 0.5% of females. The most prevalent form of color vision deficiency (color blindness) affects protans and deutans and is more commonly known as "red-green color blindness". Since there is no cure for this disorder, CVD patients opt for wearables that aid in enhancing their color perception. The most common wearable used by CVD patients is a form of tinted glass/lens. Those glasses filter out the problematic wavelengths (540-580 nm) for the red-green CVD patients using organic dyes. However, few studies have addressed the fabrication of contact lenses for color vision deficiency, and several problems related to their effectiveness and toxicity were reported. In this study, gold nanoparticles are integrated into contact lens material, thus forming nanocomposite contact lenses targeted for red-green CVD application. Three distinct sets of nanoparticles were characterized and incorporated with the hydrogel material of the lenses (pHEMA), and their resulting optical and material properties were assessed. The transmission spectra of the developed nanocomposite lenses were analogous to those of the commercial CVD wearables, and their water retention and wettability capabilities were superior to those in some of the commercially available contact lenses used for cosmetic/vision correction purposes. Hence, this work demonstrates the potential of gold nanocomposite lenses in CVD management and, more generally, color filtering applications.


Assuntos
Defeitos da Visão Cromática , Lentes de Contato , Nanopartículas Metálicas , Nanocompostos , Cor , Feminino , Ouro , Humanos , Masculino